I. Functional Requirements: The stray current detector is a safe and economical detection method for assessing the electrical interference of stray current on buried pipelines. By continuously recording the changes in pipe-to-soil potential and earth potential gradient caused by stray current over a long period, it determines the points of stray current ingress and egress, and assesses the harmful mode and location of interference. It is particularly effective in detecting dynamic interference on surrounding pipelines caused by current leakage from DC power supply systems in urban rail transit, enabling quick and convenient identification of stray current interference sources. The data recording function can continuously record for 48 hours, and through the national professional stray current Chinese analysis software, it provides authoritative evaluation result reports, making it more intuitive to analyze and judge the impact and changes of stray current.
II. Technical Parameter Requirements:
Data Channels: Multi-channel measurement of pipeline corrosion caused by stray current
Detection Functions: Pipe-to-soil potential, earth potential gradient;
Data Display: Pointer-type real-time data display;
Recording Accuracy: Data recording accuracy up to 0.1mV;
※ Synchronization Method: GPS satellite synchronization;
Sampling Frequency: Sampling frequency up to 64Hz;
Communication Method: Wireless Bluetooth, high-speed communication;
Recording Time: 24-hour data recording and storage;
Recording Medium: Universal 2GB capacity SD card;
Control Method: PDA with Android 4.0 system, 5-megapixel camera;
Battery: Rechargeable lead-acid battery, power supply for more than 36 hours;
Housing: ABS engineering plastic shell, waterproof and shockproof design;
※ Control Software: SCM-Logger controller software
※ Analysis Software: Professional SC-DView data analysis display and control software;
Working Temperature: -20℃— 50℃;
III. Stray Current Detector Controller Software:
Requirements: Used in conjunction with the stray current detector equipment, this software allows for device settings, observation of collected waveforms, viewing of collected data, and other operations. The controller can transmit data with the detection device via Bluetooth, and through the SCM-Logger controller software, it enables detection device management, setting collection parameters, test collection, formal collection, device file management, etc.
IV. Stray Current Detection and Data Analysis Software:
Requirements: Compatible with imported SCM equipment data processing and analysis, combined with GPS satellite antenna, it can achieve simultaneous detection and evaluation of multiple devices on site, reducing interference errors from multiple device detection. The instrument has a full Chinese operation interface for easy setup, and the SC-DView data analysis software provides a Chinese interface for user convenience. It can view the pipe current information provided by SCM smart sensors (signal browser), establish detection time periods and cycles, and provide a time axis basis for detection analysis. In addition to analyzing single data, the data analysis software can also perform similarity analysis, attenuation analysis, and protection effect analysis on multiple data. It can analyze and process at least 16 sets of data simultaneously, and by analyzing the similarity of stray current data, it ultimately derives the variation pattern and interference intensity coefficient of stray current, providing preliminary preparation and data support for drainage work.
※ The genuine SC-DView stray current Chinese software must be accompanied by a national copyright certificate.
V. Detailed Equipment Configuration Requirements:
JX-SCM Stray Current Detector main unit 1 set (pointer-type display), GPS satellite synchronization antenna 1 piece, external connection cables 2 pieces, charger 1 piece, SD memory card 1 piece, control terminal PDA with controller software 1 set, SC-DView stray current detection and data analysis software 1 set, warranty card 1 piece, product factory certificate 1 piece, SC-DView stray current software national copyright certificate 1 copy, equipment user manual 1 copy, stray current detector controller software user manual 1 copy, stray current detection and data analysis software manual 1 copy, packaging box 1 piece.
Company Profile: Jiangsu Yangzhou Dary Electric Co., Ltd.