Current Transformer Transient Characteristic Tester




Product Introduction;

 Type Comprehensive Parameter Tester

 Measurement Range 0-5A Main Performance Parameters: Direct excitation voltage input range: 0~100V Maximum allowable current of measuring circuit: 5A Sampling period: 1mS~50mS (20Hz~1000Hz) Maximum sampling time: 1000S Sampling digital resolution: 12-bit AD Comprehensive measurement accuracy: 2% Measurement parameters: Applied voltage 0~100V Steady-state current 0~5A DC resistance (manual input accurate value) 0~999.999Ω Transformer equivalent inductance 0~999H


Type Comprehensive Parameter Tester Brand  
Model FR-2620   Measurement Range 0-5A


Main Performance Parameters:

Direct excitation voltage input range: 0~100V

Maximum allowable current of measuring circuit: 5A

Sampling period: 1mS~50mS (20Hz~1000Hz)

Maximum sampling time: 1000S

Sampling digital resolution: 12-bit AD

Comprehensive measurement accuracy: 2%

Measurement parameters:

Applied voltage 0~100V

Steady-state current 0~5A

DC resistance (manual input accurate value) 0~999.999Ω

Transformer equivalent inductance 0~999H

Time constant 0~100 seconds

Saturation flux 0~9999 webers

Decay flux 0~9999 webers

Residual flux 0~9999 webers

Residual flux coefficient 0%~100%

Input parameters:

Transformer DC resistance; Sampling period; Load resistance; Resistance conversion coefficient

Automatically calculated parameters:

Equivalent inductance; Loaded time constant; Short-circuit time constant
; Steady-state current; Saturation flux; Decay flux; Residual flux; Residual flux coefficient; Charging time; Discharging time