Mine Stray Current Tester





 
   Model: TD-FZY-3



 Used to test stray current on steel rails, cable sheaths, metal mesh frames, etc. in underground coal mines. Prevent stray current from exceeding specified values and causing electric sparks. Ensure mine safety.



◇ Measurement Range ◇

    AC Range: 0~100mA~500mA~1A~5A

    DC Range: (+) 0~100mA~500mA~2.5A~10A~50A

    Basic Error: DC +2.5%

    AC +5%



◇ Precautions ◇

    Before measurement, insert the test leads into the internal test lead holes respectively, and insert both ends of the connecting wire into the two jacks. Adjust the meter pointer to zero.

    Place the test rods connected to the binding posts on the two points to be measured (e.g., steel rail, cable sheath, coal, etc.). Set the range switch to the appropriate position. The meter reading is the stray current value between the two points. Pointer deflection to the right indicates positive, to the left indicates negative.

    When measuring stray voltage, separate the connecting forks in the two color posts. The meter reading then indicates the voltage value, with mA corresponding to mV and A corresponding to V.

    When the stray current magnitude is unknown, first set to the maximum range, then gradually decrease to the appropriate range. The instrument should be placed horizontally.

    When the measured current exceeds 5A, only short-time measurement is allowed. When the measured current exceeds 10A, only instantaneous measurement is allowed.

    When not in use, set the instrument to the (OFF) position.



Mine Stray Current Tester